Vulnerabilities > Schneider Electric > Critical

DATE CVE VULNERABILITY TITLE RISK
2021-07-21 CVE-2021-22729 Use of Hard-coded Password vulnerability in Schneider-Electric products
A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
network
low complexity
schneider-electric CWE-259
critical
10.0
2021-07-21 CVE-2021-22707 Use of Hard-coded Credentials vulnerability in Schneider-Electric products
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
network
low complexity
schneider-electric CWE-798
critical
10.0
2021-06-11 CVE-2021-22768 Improper Input Validation vulnerability in Schneider-Electric products
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767
network
low complexity
schneider-electric CWE-20
critical
9.8
2021-06-11 CVE-2021-22767 Improper Input Validation vulnerability in Schneider-Electric products
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276
network
low complexity
schneider-electric CWE-20
critical
9.8
2021-06-11 CVE-2021-22765 Improper Input Validation vulnerability in Schneider-Electric products
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet
network
low complexity
schneider-electric CWE-20
critical
9.8
2021-06-11 CVE-2021-22763 Weak Password Recovery Mechanism for Forgotten Password vulnerability in Schneider-Electric products
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.
network
low complexity
schneider-electric CWE-640
critical
9.8
2021-05-26 CVE-2021-22737 Improper Restriction of Excessive Authentication Attempts vulnerability in Schneider-Electric Homelynk Firmware and Spacelynk Firmware
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.
network
low complexity
schneider-electric CWE-307
critical
9.8
2021-03-11 CVE-2021-22709 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
network
schneider-electric CWE-119
critical
9.3
2021-03-11 CVE-2021-22710 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
network
schneider-electric CWE-119
critical
9.3
2021-03-11 CVE-2021-22711 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric Interactive Graphical Scada System
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data.
network
schneider-electric CWE-119
critical
9.3