Vulnerabilities > Schneider Electric > Critical
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2013-01-21 | CVE-2013-0657 | Buffer Errors vulnerability in Schneider-Electric Interactive Graphical Scada System 10.0/9.0 Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol. | 10.0 |
2011-12-17 | CVE-2011-4859 | Multiple Security vulnerability in Schneider Electric Modicon Quantum The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port. | 10.0 |
2011-12-17 | CVE-2011-4860 | Improper Authentication vulnerability in Schneider-Electric products The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message. | 10.0 |
2011-12-17 | CVE-2011-4861 | Permissions, Privileges, and Access Controls vulnerability in Schneider-Electric products The modbus_125_handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502. | 10.0 |
2011-12-02 | CVE-2011-4034 | Buffer Errors vulnerability in Schneider-Electric products Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors. | 9.3 |
2011-08-16 | CVE-2011-3143 | Resource Management Errors vulnerability in multiple products Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that trigger heap memory corruption. | 10.0 |