Vulnerabilities > Yokogawa > B M9000 VP
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-04-11 | CVE-2023-26593 | Cleartext Storage of Sensitive Information vulnerability in Yokogawa products CENTUM series provided by Yokogawa Electric Corporation are vulnerable to cleartext storage of sensitive information. | 7.8 |
2022-06-28 | CVE-2022-30707 | Unspecified vulnerability in Yokogawa products Violation of secure design principles exists in the communication of CAMS for HIS. low complexity yokogawa | 8.8 |
2022-04-15 | CVE-2022-26034 | Improper Authentication vulnerability in Yokogawa B/M9000 VP and Centum VP Improper authentication vulnerability in the communication protocol provided by AD (Automation Design) server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP Small R6.01.10 to R6.09.00, CENTUM VP Basic R6.01.10 to R6.09.00, and B/M9000 VP R8.01.01 to R8.03.01 allows an attacker to use the functions provided by AD server. | 9.1 |
2022-04-15 | CVE-2022-27188 | OS Command Injection vulnerability in Yokogawa B/M9000 VP and Centum VP OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute an arbitrary OS command by altering a file generated using Graphic Builder. | 7.8 |
2019-01-09 | CVE-2018-16196 | Improper Input Validation vulnerability in Yokogawa products Multiple Yokogawa products that contain Vnet/IP Open Communication Driver (CENTUM CS 3000(R3.05.00 - R3.09.50), CENTUM CS 3000 Entry Class(R3.05.00 - R3.09.50), CENTUM VP(R4.01.00 - R6.03.10), CENTUM VP Entry Class(R4.01.00 - R6.03.10), Exaopc(R3.10.00 - R3.75.00), PRM(R2.06.00 - R3.31.00), ProSafe-RS(R1.02.00 - R4.02.00), FAST/TOOLS(R9.02.00 - R10.02.00), B/M9000 VP(R6.03.01 - R8.01.90)) allows remote attackers to cause a denial of service attack that may result in stopping Vnet/IP Open Communication Driver's communication via unspecified vectors. | 7.5 |
2018-04-17 | CVE-2018-8838 | Unspecified vulnerability in Yokogawa products A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. | 6.5 |