Vulnerabilities > Siemens > Wincc

DATE CVE VULNERABILITY TITLE RISK
2023-06-13 CVE-2023-30897 Incorrect Permission Assignment for Critical Resource vulnerability in Siemens Wincc
A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13).
local
low complexity
siemens CWE-732
7.8
2017-08-30 CVE-2017-12069 XXE vulnerability in multiple products
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367.
network
low complexity
siemens ocpfoundation CWE-611
6.4
2015-04-08 CVE-2015-2823 Improper Authentication vulnerability in Siemens Wincc
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
network
siemens CWE-287
6.8
2015-04-08 CVE-2015-2822 Improper Input Validation vulnerability in Siemens Wincc 5.0/7.0/7.1
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102.
network
siemens CWE-20
4.3
2015-02-18 CVE-2015-1358 Cryptographic Issues vulnerability in Siemens Wincc 13.0
The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack.
network
low complexity
siemens CWE-310
5.0
2014-07-24 CVE-2014-4686 Privilege Escalation vulnerability in Siemens Simatic Pcs7 and Wincc
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.
network
siemens
6.8
2014-07-24 CVE-2014-4685 Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic Pcs7 and Wincc
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
local
low complexity
siemens CWE-264
4.6
2014-07-24 CVE-2014-4684 Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic Pcs7 and Wincc
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
network
siemens CWE-264
6.0
2014-07-24 CVE-2014-4683 Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic Pcs7 and Wincc
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
network
siemens CWE-264
4.9
2014-07-24 CVE-2014-4682 Information Exposure vulnerability in Siemens Simatic Pcs7 and Wincc
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
network
low complexity
siemens CWE-200
5.0