Vulnerabilities > Siemens > Simatic Wincc Runtime Advanced

DATE CVE VULNERABILITY TITLE RISK
2021-05-12 CVE-2021-25660 Access of Memory Location After End of Buffer vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-788
5.0
2021-05-12 CVE-2021-25661 Access of Memory Location After End of Buffer vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-788
5.0
2021-05-12 CVE-2021-25662 Improper Handling of Exceptional Conditions vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-755
5.0
2021-05-12 CVE-2021-27383 Allocation of Resources Without Limits or Throttling vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-770
5.0
2021-05-12 CVE-2021-27384 Access of Memory Location After End of Buffer vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-788
7.5
2021-05-12 CVE-2021-27385 Infinite Loop vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-835
7.5
2021-05-12 CVE-2021-27386 Memory Leak vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.
network
low complexity
siemens CWE-401
5.0
2021-03-25 CVE-2021-3449 NULL Pointer Dereference vulnerability in multiple products
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client.
5.9
2020-07-14 CVE-2020-7592 Cleartext Transmission of Sensitive Information vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl.
low complexity
siemens CWE-319
3.3
2020-06-10 CVE-2020-7580 Unquoted Search Path or Element vulnerability in Siemens products
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14).
local
low complexity
siemens CWE-428
6.7