Vulnerabilities > Siemens > Simatic S7 1200 CPU 1215C Firmware > 4.0

DATE CVE VULNERABILITY TITLE RISK
2022-12-13 CVE-2021-40365 Improper Input Validation vulnerability in Siemens products
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
network
low complexity
siemens CWE-20
7.5
2022-12-13 CVE-2021-44693 Improper Validation of Specified Quantity in Input vulnerability in Siemens products
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
network
low complexity
siemens CWE-1284
4.9
2022-12-13 CVE-2021-44694 Improper Validation of Specified Type of Input vulnerability in Siemens products
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
network
low complexity
siemens CWE-1287
5.5
2022-12-13 CVE-2021-44695 Improper Validation of Syntactic Correctness of Input vulnerability in Siemens products
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
network
low complexity
siemens CWE-1286
4.9
2019-08-13 CVE-2019-10943 Missing Support for Integrity Check vulnerability in Siemens products
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl.
network
low complexity
siemens CWE-353
5.0
2019-08-13 CVE-2019-10929 Use of a Broken or Risky Cryptographic Algorithm vulnerability in Siemens products
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl.
network
siemens CWE-327
4.3
2013-04-22 CVE-2013-2780 Unspecified vulnerability in Siemens products
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
network
low complexity
siemens
7.8
2013-04-22 CVE-2013-0700 Unspecified vulnerability in Siemens products
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
network
low complexity
siemens
7.8