Vulnerabilities > Siemens > Simatic S7 1200 CPU 1215 FC Firmware
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-12-13 | CVE-2021-40365 | Improper Input Validation vulnerability in Siemens products Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. | 7.5 |
2022-12-13 | CVE-2021-44693 | Improper Validation of Specified Quantity in Input vulnerability in Siemens products Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. | 4.9 |
2022-12-13 | CVE-2021-44694 | Improper Validation of Specified Type of Input vulnerability in Siemens products Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. | 5.5 |
2022-12-13 | CVE-2021-44695 | Improper Validation of Syntactic Correctness of Input vulnerability in Siemens products Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. | 4.9 |
2022-11-08 | CVE-2022-30694 | Cross-Site Request Forgery (CSRF) vulnerability in Siemens products A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. | 3.5 |
2021-03-25 | CVE-2021-3449 | NULL Pointer Dereference vulnerability in multiple products An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. | 5.9 |
2013-04-22 | CVE-2013-2780 | Unspecified vulnerability in Siemens products Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). | 7.8 |
2013-04-22 | CVE-2013-0700 | Unspecified vulnerability in Siemens products Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port). | 7.8 |
2012-10-10 | CVE-2012-3040 | Cross-site Scripting vulnerability in Siemens products Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. | 4.3 |
2012-09-25 | CVE-2012-3037 | Improper Certificate Validation vulnerability in Siemens products The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate. | 4.3 |