Vulnerabilities > Siemens > Simatic HMI KTP Mobile Panels Ktp700 Firmware > High
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2021-05-12 | CVE-2021-25660 | Access of Memory Location After End of Buffer vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. | 7.5 |
2021-05-12 | CVE-2021-25661 | Access of Memory Location After End of Buffer vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. | 7.5 |
2021-05-12 | CVE-2021-25662 | Improper Handling of Exceptional Conditions vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. | 7.5 |
2021-05-12 | CVE-2021-27383 | Allocation of Resources Without Limits or Throttling vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. | 7.5 |
2021-05-12 | CVE-2021-27385 | Infinite Loop vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. | 7.5 |
2021-05-12 | CVE-2021-27386 | Memory Leak vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. | 7.5 |
2019-05-14 | CVE-2019-6576 | Cryptographic Issues vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). | 7.5 |
2019-04-17 | CVE-2019-6575 | Uncaught Exception vulnerability in Siemens products A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. | 7.5 |
2019-04-17 | CVE-2019-6568 | Out-of-bounds Read vulnerability in Siemens products The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. | 7.5 |
2018-12-13 | CVE-2018-13814 | Improper Input Validation vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). | 8.8 |