Vulnerabilities > Siemens > Scalance S615 Firmware

DATE CVE VULNERABILITY TITLE RISK
2021-03-15 CVE-2021-25676 Improper Restriction of Excessive Authentication Attempts vulnerability in Siemens products
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3).
network
low complexity
siemens CWE-307
5.0
2021-03-15 CVE-2021-25667 Stack-based Buffer Overflow vulnerability in Siemens products
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2).
low complexity
siemens CWE-121
8.8
2020-02-11 CVE-2019-13946 Resource Exhaustion vulnerability in Siemens products
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface.
network
low complexity
siemens CWE-400
7.8
2018-09-06 CVE-2018-5391 Improper Input Validation vulnerability in multiple products
The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly.
7.5
2017-10-04 CVE-2017-14491 Out-of-bounds Write vulnerability in multiple products
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.
9.8
2017-05-11 CVE-2017-2681 Resource Exhaustion vulnerability in Siemens products
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product.
low complexity
siemens CWE-400
6.1
2017-05-11 CVE-2017-2680 Resource Exhaustion vulnerability in Siemens products
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2).
low complexity
siemens CWE-400
6.1
2016-09-29 CVE-2016-7090 Information Exposure vulnerability in Siemens Scalance M-800 Firmware and Scalance S615 Firmware
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
network
siemens CWE-200
4.3