DATE CVE VULNERABILITY TITLE RISK
2022-10-11 CVE-2022-31766 Improper Input Validation vulnerability in Siemens products
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions < V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (All versions < V7.1.2), SCALANCE M804PB (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (Annex A) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (Annex B) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (Annex A) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (Annex B) (All versions < V7.1.2), SCALANCE M826-2 SHDSL-Router (All versions < V7.1.2), SCALANCE M874-2 (All versions < V7.1.2), SCALANCE M874-3 (All versions < V7.1.2), SCALANCE M876-3 (EVDO) (All versions < V7.1.2), SCALANCE M876-3 (ROK) (All versions < V7.1.2), SCALANCE M876-4 (All versions < V7.1.2), SCALANCE M876-4 (EU) (All versions < V7.1.2), SCALANCE M876-4 (NAM) (All versions < V7.1.2), SCALANCE MUM853-1 (EU) (All versions < V7.1.2), SCALANCE MUM856-1 (EU) (All versions < V7.1.2), SCALANCE MUM856-1 (RoW) (All versions < V7.1.2), SCALANCE S615 (All versions < V7.1.2), SCALANCE S615 EEC (All versions < V7.1.2), SCALANCE WAM763-1 (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 (EU) (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 (US) (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 EEC (EU) (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 EEC (US) (All versions >= V1.1.0 < V2.0), SCALANCE WUM763-1 (All versions >= V1.1.0 < V2.0), SCALANCE WUM763-1 (All versions >= V1.1.0 < V2.0), SCALANCE WUM766-1 (EU) (All versions >= V1.1.0 < V2.0), SCALANCE WUM766-1 (US) (All versions >= V1.1.0 < V2.0).
network
low complexity
siemens CWE-20
8.6
2021-07-13 CVE-2020-28400 Allocation of Resources Without Limits or Throttling vulnerability in Siemens products
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition.
network
low complexity
siemens CWE-770
5.0
2021-03-15 CVE-2021-25667 Stack-based Buffer Overflow vulnerability in Siemens products
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2).
low complexity
siemens CWE-121
8.8
2018-09-06 CVE-2018-5391 Improper Input Validation vulnerability in multiple products
The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly.
7.5