2019-03-08 | CVE-2019-8269 | Out-of-bounds Write vulnerability in multiple products UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. | 5.0 |
2019-03-05 | CVE-2019-8263 | Out-of-bounds Write vulnerability in multiple products UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. | 4.3 |
2019-03-05 | CVE-2019-8259 | Memory Leak vulnerability in multiple products UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. | 5.0 |
2019-01-31 | CVE-2019-6111 | Path Traversal vulnerability in multiple products An issue was discovered in OpenSSH 7.9. | 5.9 |
2019-01-31 | CVE-2019-6110 | Inappropriate Encoding for Output Context vulnerability in multiple products In OpenSSH 7.9, due to accepting and displaying arbitrary stderr output from the server, a malicious server (or Man-in-The-Middle attacker) can manipulate the client output, for example to use ANSI control codes to hide additional files being transferred. | 6.8 |
2019-01-31 | CVE-2019-6109 | Improper Encoding or Escaping of Output vulnerability in multiple products An issue was discovered in OpenSSH 7.9. | 6.8 |
2019-01-10 | CVE-2018-20685 | Incorrect Authorization vulnerability in multiple products In OpenSSH 7.9, scp.c in the scp client allows remote SSH servers to bypass intended access restrictions via the filename of . | 5.3 |
2018-12-13 | CVE-2018-13815 | Resource Exhaustion vulnerability in Siemens Simatic S7-1200 Firmware and Simatic S7-1500 Firmware A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). | 5.0 |
2018-12-13 | CVE-2018-13814 | Improper Input Validation vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). | 6.8 |
2018-12-13 | CVE-2018-13813 | Open Redirect vulnerability in Siemens products A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). | 5.8 |