Vulnerabilities > Siemens > High

DATE CVE VULNERABILITY TITLE RISK
2019-08-05 CVE-2019-12264 Argument Injection or Modification vulnerability in multiple products
Wind River VxWorks 6.6, 6.7, 6.8, 6.9.3, 6.9.4, and Vx7 has Incorrect Access Control in IPv4 assignment by the ipdhcpc DHCP client component.
low complexity
windriver belden siemens CWE-88
7.1
2019-07-11 CVE-2019-10935 Unrestricted Upload of File with Dangerous Type vulnerability in Siemens Simatic PCS 7, Simatic Wincc and Simatic Wincc Runtime
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3).
network
low complexity
siemens CWE-434
7.2
2019-07-11 CVE-2019-10931 Unspecified vulnerability in Siemens products
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59).
network
low complexity
siemens
7.5
2019-07-11 CVE-2019-10930 Unrestricted Upload of File with Dangerous Type vulnerability in Siemens products
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions).
network
low complexity
siemens CWE-434
7.5
2019-07-11 CVE-2019-10915 Missing Authentication for Critical Function vulnerability in Siemens Sinetplan and TIA Administrator
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1).
local
low complexity
siemens CWE-306
7.8
2019-06-12 CVE-2019-6584 Insufficient Session Expiration vulnerability in Siemens Logo!8 Firmware 1.80.00/1.81.00
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02).
network
low complexity
siemens CWE-613
8.8
2019-06-12 CVE-2019-6582 Incorrect Authorization vulnerability in Siemens products
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a).
network
low complexity
siemens CWE-863
7.1
2019-06-12 CVE-2019-6581 Unspecified vulnerability in Siemens products
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a).
network
low complexity
siemens
8.8
2019-06-12 CVE-2019-6571 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Siemens Logo!8 Firmware 1.80.00/1.81.00
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02).
network
low complexity
siemens CWE-119
7.5
2019-06-12 CVE-2019-10925 Improper Access Control vulnerability in Siemens Simatic Mv420 Firmware and Simatic Mv440 Firmware
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6).
network
low complexity
siemens CWE-284
7.1