Vulnerabilities > Siemens > High

DATE CVE VULNERABILITY TITLE RISK
2016-06-27 CVE-2016-3949 Resource Management Errors vulnerability in Siemens products
Siemens SIMATIC S7-300 Profinet-enabled CPU devices with firmware before 3.2.12 and SIMATIC S7-300 Profinet-disabled CPU devices with firmware before 3.3.12 allow remote attackers to cause a denial of service (defect-mode transition) via crafted (1) ISO-TSAP or (2) Profibus packets.
network
low complexity
siemens CWE-399
7.5
2016-02-08 CVE-2016-2200 Improper Input Validation vulnerability in Siemens Simatic S7-1500 CPU Firmware 1.5.1/1.6/1.8.2
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102.
network
low complexity
siemens CWE-20
7.5
2016-01-26 CVE-2015-7974 Improper Authentication vulnerability in multiple products
NTP 4.x before 4.2.8p6 and 4.3.x before 4.3.90 do not verify peer associations of symmetric keys when authenticating packets, which might allow remote attackers to conduct impersonation attacks via an arbitrary trusted key, aka a "skeleton key."
network
low complexity
ntp siemens netapp debian CWE-287
7.7
2014-06-05 CVE-2014-0224 Inadequate Encryption Strength vulnerability in multiple products
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability.
7.4
2014-04-07 CVE-2014-0160 Out-of-bounds Read vulnerability in multiple products
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug.
7.5
2010-07-22 CVE-2010-2772 Use of Hard-coded Credentials vulnerability in Siemens Simatic PCS 7 and Simatic Wincc
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
local
low complexity
siemens CWE-798
7.8