Vulnerabilities > Siemens

DATE CVE VULNERABILITY TITLE RISK
2019-01-10 CVE-2018-20685 Incorrect Authorization vulnerability in multiple products
In OpenSSH 7.9, scp.c in the scp client allows remote SSH servers to bypass intended access restrictions via the filename of .
5.3
2018-12-19 CVE-2018-20019 Out-of-bounds Write vulnerability in multiple products
LibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code execution
network
low complexity
libvnc-project canonical debian siemens CWE-787
critical
9.8
2018-12-13 CVE-2018-16555 Cross-site Scripting vulnerability in Siemens products
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1).
network
low complexity
siemens CWE-79
5.4
2018-12-13 CVE-2018-13815 Resource Exhaustion vulnerability in Siemens Simatic S7-1200 Firmware and Simatic S7-1500 Firmware
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6).
network
low complexity
siemens CWE-400
7.5
2018-12-13 CVE-2018-13814 Improper Input Validation vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions).
network
low complexity
siemens CWE-20
8.8
2018-12-13 CVE-2018-13813 Open Redirect vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions).
network
low complexity
siemens CWE-601
8.1
2018-12-13 CVE-2018-13812 Path Traversal vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions).
network
low complexity
siemens CWE-22
7.5
2018-12-13 CVE-2018-13811 Information Exposure vulnerability in Siemens Simatic Step 7 (Tia Portal)
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1).
local
low complexity
siemens CWE-200
5.5
2018-12-13 CVE-2018-13804 Unspecified vulnerability in Siemens products
A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4).
network
high complexity
siemens
8.1
2018-12-12 CVE-2018-13816 Improper Authentication vulnerability in Siemens TIM 1531 IRC Firmware 1.1
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0).
network
low complexity
siemens CWE-287
critical
10.0