Vulnerabilities > Selinc
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-05-10 | CVE-2023-31157 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31158 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31159 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31160 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31161 | Improper Input Validation vulnerability in Selinc products An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service Bulletin dated 2022-11-15 for more details. | 8.8 |
2023-05-10 | CVE-2023-31162 | Improper Input Validation vulnerability in Selinc products An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file. See SEL Service Bulletin dated 2022-11-15 for more details. | 4.3 |
2023-05-10 | CVE-2023-31163 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31164 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31165 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31166 | Path Traversal vulnerability in Selinc products An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See SEL Service Bulletin dated 2022-11-15 for more details. | 4.3 |