Vulnerabilities > Schneider Electric > Critical
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-02-09 | CVE-2022-22810 | Unspecified vulnerability in Schneider-Electric products A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. | 9.8 |
2022-02-09 | CVE-2022-22813 | Unspecified vulnerability in Schneider-Electric products A CWE-798: Use of Hard-coded Credentials vulnerability exists. | 9.8 |
2022-02-09 | CVE-2022-24310 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. | 9.8 |
2022-02-09 | CVE-2022-24311 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. | 9.8 |
2022-02-09 | CVE-2022-24312 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. | 9.8 |
2022-02-09 | CVE-2022-24313 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System Data Server A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. | 9.8 |
2022-01-28 | CVE-2021-22820 | Insufficient Session Expiration vulnerability in Schneider-Electric products A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. | 9.8 |
2021-09-02 | CVE-2021-22704 | Unspecified vulnerability in Schneider-Electric Ecostruxure Machine Expert and Vijeo Designer A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. | 9.1 |
2021-07-21 | CVE-2021-22707 | Unspecified vulnerability in Schneider-Electric products A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges. | 9.8 |
2021-07-21 | CVE-2021-22727 | Unspecified vulnerability in Schneider-Electric products A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized access to the charging station web server | 9.8 |