Vulnerabilities > Schneider Electric
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2018-03-09 | CVE-2018-7237 | Improper Input Validation vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file' | 9.1 |
2018-03-09 | CVE-2018-7236 | Improper Authentication vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service. | 8.1 |
2018-03-09 | CVE-2018-7235 | Improper Input Validation vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file' | 7.5 |
2018-03-09 | CVE-2018-7234 | Improper Certificate Validation vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate. | 7.5 |
2018-03-09 | CVE-2018-7233 | Improper Input Validation vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'. | 9.8 |
2018-03-09 | CVE-2018-7232 | Improper Input Validation vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'. | 9.8 |
2018-03-09 | CVE-2018-7231 | Improper Input Validation vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'. | 9.8 |
2018-03-09 | CVE-2018-7230 | XXE vulnerability in Schneider-Electric products A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67. | 8.8 |
2018-03-09 | CVE-2018-7229 | Use of Hard-coded Credentials vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials. | 9.8 |
2018-03-09 | CVE-2018-7228 | Improper Authentication vulnerability in Schneider-Electric products A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges. | 9.8 |