2022-01-28 | CVE-2021-22819 | Improper Restriction of Rendered UI Layers or Frames vulnerability in Schneider-Electric products A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. | 4.3 |
2022-01-28 | CVE-2021-22820 | Insufficient Session Expiration vulnerability in Schneider-Electric products A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. | 9.8 |
2022-01-28 | CVE-2021-22821 | Server-Side Request Forgery (SSRF) vulnerability in Schneider-Electric products A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. | 8.6 |
2022-01-28 | CVE-2021-22822 | Cross-site Scripting vulnerability in Schneider-Electric products A CWE-79 Improper Neutralization of Input During Web Page Generation (?Cross-site Scripting?) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. | 6.1 |
2022-01-28 | CVE-2021-22825 | Information Exposure vulnerability in Schneider-Electric products A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. | 8.0 |
2022-01-28 | CVE-2021-22826 | Improper Input Validation vulnerability in Schneider-Electric Ecostruxure Power Monitoring Expert A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. | 8.8 |
2022-01-28 | CVE-2021-22827 | Improper Input Validation vulnerability in Schneider-Electric Ecostruxure Power Monitoring Expert A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. | 8.8 |
2021-09-02 | CVE-2021-22704 | Unspecified vulnerability in Schneider-Electric Ecostruxure Machine Expert and Vijeo Designer A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. | 9.1 |
2021-09-02 | CVE-2021-22775 | Unspecified vulnerability in Schneider-Electric Gp-Pro EX A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software. | 7.8 |
2021-09-02 | CVE-2021-22789 | Unspecified vulnerability in Schneider-Electric products A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | 6.5 |