DATE CVE VULNERABILITY TITLE RISK
2023-02-01 CVE-2021-22786 Unspecified vulnerability in Schneider-Electric products
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol.
network
low complexity
schneider-electric
7.5
2023-01-31 CVE-2022-45789 Unspecified vulnerability in Schneider-Electric products
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session.
network
low complexity
schneider-electric
critical
9.8
2023-01-30 CVE-2022-45788 Unspecified vulnerability in Schneider-Electric products
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller.
network
low complexity
schneider-electric
critical
9.8
2022-11-22 CVE-2022-0222 Improper Privilege Management vulnerability in Schneider-Electric products
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP.
network
low complexity
schneider-electric CWE-269
7.5
2022-09-12 CVE-2022-37300 Unspecified vulnerability in Schneider-Electric products
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus.
network
low complexity
schneider-electric
critical
9.8
2019-03-21 CVE-2015-6462 Cross-site Scripting vulnerability in Schneider-Electric products
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
network
low complexity
schneider-electric CWE-79
5.4
2019-03-21 CVE-2015-6461 Improper Input Validation vulnerability in Schneider-Electric products
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
network
low complexity
schneider-electric CWE-20
5.4
2017-06-30 CVE-2017-6017 Resource Exhaustion vulnerability in Schneider-Electric products
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H.
network
low complexity
schneider-electric CWE-400
7.5