Vulnerabilities > Schneider Electric > Modicon M340 Bmxp342020 Firmware
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2019-03-21 | CVE-2015-6461 | Improper Input Validation vulnerability in Schneider-Electric products Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. | 5.4 |
2018-04-18 | CVE-2018-7762 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | 7.5 |
2018-04-18 | CVE-2018-7761 | Improper Input Validation vulnerability in Schneider-Electric products A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. | 9.8 |
2018-04-18 | CVE-2018-7760 | Improper Authentication vulnerability in Schneider-Electric products An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. | 9.8 |
2018-04-18 | CVE-2018-7759 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. | 7.5 |
2018-04-18 | CVE-2018-7242 | Inadequate Encryption Strength vulnerability in Schneider-Electric products Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. | 9.8 |
2018-04-18 | CVE-2018-7241 | Use of Hard-coded Credentials vulnerability in Schneider-Electric products Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. | 9.8 |
2017-06-30 | CVE-2017-6017 | Resource Exhaustion vulnerability in Schneider-Electric products A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. | 7.5 |
2014-10-03 | CVE-2014-0754 | Path Traversal vulnerability in Schneider-Electric products Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request. | 10.0 |