DATE CVE VULNERABILITY TITLE RISK
2020-12-11 CVE-2020-7540 Missing Authentication for Critical Function vulnerability in Schneider-Electric products
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
network
low complexity
schneider-electric CWE-306
critical
9.8
2020-12-11 CVE-2020-7539 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the controller over HTTP.
network
low complexity
schneider-electric CWE-754
7.5
2020-12-11 CVE-2020-7537 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
network
low complexity
schneider-electric CWE-754
7.5
2020-12-11 CVE-2020-7536 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP.
network
low complexity
schneider-electric CWE-754
7.5
2020-12-11 CVE-2020-7535 Path Traversal vulnerability in Schneider-Electric products
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP.
network
low complexity
schneider-electric CWE-22
7.5
2020-12-01 CVE-2020-7533 Unspecified vulnerability in Schneider-Electric products
A CWE-255: Credentials Management vulnerability exists in Web Server on Modicon M340, Modicon Quantum and ModiconPremium Legacy offers and their Communication Modules (see security notification for version information) which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
network
low complexity
schneider-electric
critical
9.8
2020-01-06 CVE-2019-6855 Incorrect Authorization vulnerability in Schneider-Electric products
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
network
low complexity
schneider-electric CWE-863
7.5
2018-04-18 CVE-2018-7762 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
network
low complexity
schneider-electric CWE-119
7.5
2018-04-18 CVE-2018-7761 Improper Input Validation vulnerability in Schneider-Electric products
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
network
low complexity
schneider-electric CWE-20
critical
9.8
2018-04-18 CVE-2018-7760 Improper Authentication vulnerability in Schneider-Electric products
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.
network
low complexity
schneider-electric CWE-287
critical