Vulnerabilities > Schneider Electric > Ibp219 1ER Firmware

DATE CVE VULNERABILITY TITLE RISK
2018-07-03 CVE-2018-7782 Insufficiently Protected Credentials vulnerability in Schneider-Electric products
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
network
low complexity
schneider-electric CWE-522
4.0
2018-07-03 CVE-2018-7781 Missing Encryption of Sensitive Data vulnerability in Schneider-Electric products
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
network
low complexity
schneider-electric CWE-311
4.0
2018-07-03 CVE-2018-7780 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".
network
low complexity
schneider-electric CWE-119
7.5
2018-03-09 CVE-2018-7238 Classic Buffer Overflow vulnerability in Schneider-Electric products
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.
network
low complexity
schneider-electric CWE-120
7.5
2018-03-09 CVE-2018-7237 Improper Input Validation vulnerability in Schneider-Electric products
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'
network
low complexity
schneider-electric CWE-20
6.4
2018-03-09 CVE-2018-7236 Improper Authentication vulnerability in Schneider-Electric products
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
5.8
2018-03-09 CVE-2018-7235 Improper Input Validation vulnerability in Schneider-Electric products
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'
network
low complexity
schneider-electric CWE-20
7.8
2018-03-09 CVE-2018-7234 Improper Certificate Validation vulnerability in Schneider-Electric products
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.
network
low complexity
schneider-electric CWE-295
7.8
2018-03-09 CVE-2018-7233 Improper Input Validation vulnerability in Schneider-Electric products
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.
network
low complexity
schneider-electric CWE-20
7.5
2018-03-09 CVE-2018-7232 Improper Input Validation vulnerability in Schneider-Electric products
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
network
low complexity
schneider-electric CWE-20
7.5