Vulnerabilities > Rockwellautomation > Rslinx Classic
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-06-15 | CVE-2020-12005 | Unrestricted Upload of File with Dangerous Type vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. | 7.5 |
2020-06-15 | CVE-2020-12003 | Path Traversal vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. | 7.5 |
2020-06-15 | CVE-2020-12001 | Improper Input Validation vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. | 9.8 |
2020-06-15 | CVE-2020-11999 | Improper Input Validation vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. | 8.1 |
2020-04-13 | CVE-2020-10642 | Unspecified vulnerability in Rockwellautomation Rslinx Classic 4.1.00/4.11.00 In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic. | 7.8 |
2018-06-07 | CVE-2018-10619 | Unquoted Search Path or Element vulnerability in Rockwellautomation Factorytalk Linx Gateway and Rslinx Classic An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation. | 7.8 |