Vulnerabilities > Rockwellautomation > Medium
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-10-14 | CVE-2020-6083 | Classic Buffer Overflow vulnerability in Rockwellautomation Allen-Bradley Flex IO 1794-Aent/B Firmware 4.003 An exploitable denial of service vulnerability exists in the ENIP Request Path Port Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. | 5.0 |
2020-07-20 | CVE-2020-12031 | Out-of-bounds Write vulnerability in Rockwellautomation Factorytalk View In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. | 4.6 |
2020-07-20 | CVE-2020-12028 | Missing Authentication for Critical Function vulnerability in Rockwellautomation Factorytalk View In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. | 5.5 |
2020-07-20 | CVE-2020-12027 | Unspecified vulnerability in Rockwellautomation Factorytalk View All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. | 4.0 |
2020-07-20 | CVE-2020-12029 | Improper Input Validation vulnerability in Rockwellautomation Factorytalk View All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. | 6.8 |
2020-07-14 | CVE-2020-12025 | XXE vulnerability in Rockwellautomation Studio 5000 Logix Designer 32.00/32.01/32.02 Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program. | 4.3 |
2020-06-23 | CVE-2020-12033 | Improper Input Validation vulnerability in Rockwellautomation Factorytalk Services Platform In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges. | 5.8 |
2020-06-15 | CVE-2020-12003 | Path Traversal vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. | 5.0 |
2020-06-15 | CVE-2020-11999 | Improper Input Validation vulnerability in Rockwellautomation Factorytalk Linx and Rslinx Classic FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. | 5.5 |
2020-05-20 | CVE-2020-12034 | SQL Injection vulnerability in Rockwellautomation products Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. | 4.8 |