Vulnerabilities > Philips > Low
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-08-21 | CVE-2020-16237 | Improper Input Validation vulnerability in Philips Suresigns VS4 Firmware Philips SureSigns VS4, A.07.107 and prior. | 2.1 |
2020-08-21 | CVE-2020-16241 | Incorrect Authorization vulnerability in Philips Suresigns VS4 Firmware A.07.107 Philips SureSigns VS4, A.07.107 and prior. | 2.1 |
2020-06-26 | CVE-2020-14477 | Improper Authentication vulnerability in Philips products In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information. | 3.6 |
2020-06-11 | CVE-2020-12023 | Information Exposure Through Log Files vulnerability in Philips Intellibridge Enterprise B.12 Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). | 2.7 |
2019-12-20 | CVE-2019-18263 | Inadequate Encryption Strength vulnerability in Philips products An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). | 3.3 |
2019-11-26 | CVE-2019-18241 | Inadequate Encryption Strength vulnerability in Philips products In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. | 3.3 |
2019-09-04 | CVE-2019-10988 | Information Exposure vulnerability in Philips HDI 4000 Firmware In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. | 3.6 |
2019-07-24 | CVE-2019-10968 | Improper Access Control vulnerability in Philips Zymed Holter 2010 Philips Holter 2010 Plus, all versions. | 2.1 |
2018-11-19 | CVE-2018-17906 | Credentials Management vulnerability in Philips Intellispace Pacs and Isite Pacs Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. | 3.3 |
2018-09-26 | CVE-2018-8842 | Cleartext Transmission of Sensitive Information vulnerability in Philips E-Alert Firmware Philips e-Alert Unit (non-medical device), Version R2.1 and prior. | 3.3 |