Vulnerabilities > GE > Intelligent Platforms Proficy HMI Scada Cimplicity > High

DATE CVE VULNERABILITY TITLE RISK
2014-01-25 CVE-2014-0751 Path Traversal vulnerability in GE products
Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623.
network
low complexity
ge CWE-22
7.5
2014-01-25 CVE-2014-0750 Path Traversal vulnerability in GE products
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.
network
low complexity
ge CWE-22
7.5
2013-11-22 CVE-2013-2811 Improper Input Validation vulnerability in multiple products
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
7.1