DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-05-15 | CVE-2020-12834 | Incorrect Default Permissions vulnerability in Eq-3 Ccu3 Firmware and Homematic Ccu2 Firmware eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset). | 7.5 |
2019-08-07 | CVE-2019-14474 | Improper Input Validation vulnerability in Eq-3 Ccu3 Firmware eQ-3 Homematic CCU3 3.47.15 and prior has Improper Input Validation in function 'Call()' of ReGa core logic process, resulting in the ability to start a Denial of Service. | 5.0 |
2019-08-06 | CVE-2019-14473 | Missing Authorization vulnerability in Eq-3 Ccu2 Firmware and Ccu3 Firmware eQ-3 Homematic CCU2 and CCU3 use session IDs for authentication but lack authorization checks. | 6.5 |
2019-08-05 | CVE-2019-14475 | Missing Authorization vulnerability in Eq-3 Ccu2 Firmware and Ccu3 Firmware eQ-3 Homematic CCU2 2.47.15 and prior and CCU3 3.47.15 and prior use session IDs for authentication but lack authorization checks. | 5.0 |
2019-07-10 | CVE-2019-10122 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Eq-3 Ccu2 Firmware and Ccu3 Firmware eQ-3 HomeMatic CCU2 devices before 2.41.9 and CCU3 devices before 3.43.16 have buffer overflows in the ReGa ise GmbH HTTP-Server 2.0 component, aka HMCCU-179. | 7.5 |
2019-07-10 | CVE-2019-10121 | Missing Authentication for Critical Function vulnerability in Eq-3 Ccu2 Firmware and Ccu3 Firmware eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. | 7.5 |
2019-07-10 | CVE-2019-10120 | Session Fixation vulnerability in Eq-3 Ccu2 Firmware and Ccu3 Firmware On eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16, automatic login configuration (aka setAutoLogin) can be achieved by continuing to use a session ID after a logout, aka HMCCU-154. | 6.5 |
2019-07-10 | CVE-2019-10119 | Missing Authentication for Critical Function vulnerability in Eq-3 Ccu2 Firmware and Ccu3 Firmware eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. | 7.5 |
2019-05-13 | CVE-2019-9727 | Missing Authentication for Critical Function vulnerability in Eq-3 Ccu3 Firmware Unauthenticated password hash disclosure in the User.getUserPWD method in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to retrieve the GUI password hashes of GUI users. | 5.0 |
2019-05-13 | CVE-2019-9726 | Path Traversal vulnerability in Eq-3 Ccu3 Firmware Directory Traversal / Arbitrary File Read in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to read arbitrary files of the device's filesystem. | 5.0 |