Vulnerabilities > Access of Resource Using Incompatible Type ('Type Confusion')
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2021-12-23 | CVE-2021-4056 | Type Confusion vulnerability in multiple products Type confusion in loader in Google Chrome prior to 96.0.4664.93 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. | 8.8 |
2021-12-23 | CVE-2021-4061 | Type Confusion vulnerability in multiple products Type confusion in V8 in Google Chrome prior to 96.0.4664.93 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. | 8.8 |
2021-12-23 | CVE-2021-4078 | Type Confusion vulnerability in multiple products Type confusion in V8 in Google Chrome prior to 96.0.4664.93 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. | 6.8 |
2021-12-13 | CVE-2021-24045 | Type Confusion vulnerability in Facebook Hermes A type confusion vulnerability could be triggered when resolving the "typeof" unary operator in Facebook Hermes prior to v0.10.0. | 6.8 |
2021-11-23 | CVE-2021-38001 | Type Confusion vulnerability in multiple products Type confusion in V8 in Google Chrome prior to 95.0.4638.69 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. | 8.8 |
2021-11-17 | CVE-2021-41190 | Type Confusion vulnerability in multiple products The OCI Distribution Spec project defines an API protocol to facilitate and standardize the distribution of content. | 5.0 |
2021-11-10 | CVE-2021-40871 | Type Confusion vulnerability in Softing products An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66. | 5.0 |
2021-11-10 | CVE-2021-40872 | Type Confusion vulnerability in Softing Smartlink Hw-Dp and Uatoolkit Embedded An issue was discovered in Softing Industrial Automation uaToolkit Embedded before 1.40. | 5.0 |
2021-11-09 | CVE-2021-31344 | Type Confusion vulnerability in Siemens products A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). | 5.0 |
2021-11-03 | CVE-2021-23472 | Type Confusion vulnerability in Bootstrap-Table Bootstrap Table This affects versions before 1.19.1 of package bootstrap-table. | 6.1 |