2021-09-23 | CVE-2021-32987 | NULL Pointer Dereference vulnerability in Aveva Suitelink Null pointer dereference in SuiteLink server while processing command 0x0b | 7.5 |
2021-09-23 | CVE-2021-32999 | Improper Handling of Exceptional Conditions vulnerability in Aveva Suitelink Improper handling of exceptional conditions in SuiteLink server while processing command 0x01 | 7.5 |
2020-01-14 | CVE-2019-13537 | Out-of-bounds Write vulnerability in Aveva Iec870Ip Firmware 4.14.02 The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash. | 7.5 |
2019-04-11 | CVE-2019-6525 | Improper Privilege Management vulnerability in Aveva Wonderware System Platform 2014/2017 AVEVA Wonderware System Platform 2017 Update 2 and prior uses an ArchestrA network user account for authentication of system processes and inter-node communications. | 8.8 |
2019-02-13 | CVE-2019-6545 | Unspecified vulnerability in Aveva Indusoft web Studio and Intouch Machine Edition 2014 AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. | 7.5 |
2018-05-14 | CVE-2017-6021 | Improper Input Validation vulnerability in multiple products In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. | 7.5 |
2017-09-26 | CVE-2017-9962 | Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Aveva Clearscada Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. | 7.5 |
2017-04-20 | CVE-2017-5156 | Cross-Site Request Forgery (CSRF) vulnerability in Aveva Wonderware Intouch Access Anywhere 11.5.2 A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. | 8.8 |