Vulnerabilities > CVE-2022-42784 - Unspecified vulnerability in Siemens products

047910
CVSS 6.8 - MEDIUM
Attack vector
PHYSICAL
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
HIGH
Integrity impact
HIGH
Availability impact
HIGH
low complexity
siemens

Summary

A vulnerability has been identified in LOGO! 12/24RCE (All versions >= V8.3), LOGO! 12/24RCEo (All versions >= V8.3), LOGO! 230RCE (All versions >= V8.3), LOGO! 230RCEo (All versions >= V8.3), LOGO! 24CE (All versions >= V8.3), LOGO! 24CEo (All versions >= V8.3), LOGO! 24RCE (All versions >= V8.3), LOGO! 24RCEo (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (All versions >= V8.3), SIPLUS LOGO! 230RCE (All versions >= V8.3), SIPLUS LOGO! 230RCEo (All versions >= V8.3), SIPLUS LOGO! 24CE (All versions >= V8.3), SIPLUS LOGO! 24CEo (All versions >= V8.3), SIPLUS LOGO! 24RCE (All versions >= V8.3), SIPLUS LOGO! 24RCEo (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.