Vulnerabilities > CVE-2020-5807 - Improper Handling of Exceptional Conditions vulnerability in Rockwellautomation Factorytalk Diagnostics 6.11

047910
CVSS 5.0 - MEDIUM
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
NONE
Integrity impact
NONE
Availability impact
PARTIAL
network
low complexity
rockwellautomation
CWE-755

Summary

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.