Vulnerabilities > CVE-2017-12556 - Deserialization of Untrusted Data vulnerability in HP Intelligent Management Center

047910
CVSS 10.0 - CRITICAL
Attack vector
NETWORK
Attack complexity
LOW
Privileges required
NONE
Confidentiality impact
COMPLETE
Integrity impact
COMPLETE
Availability impact
COMPLETE
network
low complexity
hp
CWE-502
critical
nessus

Summary

A Remote Code Execution vulnerability in HPE intelligent Management Center (iMC) PLAT version IMC Plat 7.3 E0504P2 and earlier was found.

Common Weakness Enumeration (CWE)

Nessus

NASL familyMisc.
NASL idHP_IMC_73_E0506P03.NASL
descriptionThe version of HPE Intelligent Management Center (iMC) PLAT installed on the remote host is prior to 7.3 E0506P03. It is, therefore, affected by multiple vulnerabilities that can be exploited to execute arbitrary code. Note that Intelligent Management Center (iMC) is an HPE product; however, it is branded as H3C.
last seen2020-06-01
modified2020-06-02
plugin id103696
published2017-10-06
reporterThis script is Copyright (C) 2017-2019 and is owned by Tenable, Inc. or an Affiliate thereof.
sourcehttps://www.tenable.com/plugins/nessus/103696
titleH3C / HPE Intelligent Management Center PLAT < 7.3 E0506P03 Multiple Vulnerabilities
code
#
# (C) Tenable Network Security, Inc.
#

include("compat.inc");

if (description)
{
  script_id(103696);
  script_version("1.7");
  script_cvs_date("Date: 2019/11/12");

  script_cve_id(
    "CVE-2017-12554",
    "CVE-2017-12556",
    "CVE-2017-12557",
    "CVE-2017-12558",
    "CVE-2017-12559",
    "CVE-2017-12560",
    "CVE-2017-12561"
  );
  script_xref(name:"HP", value:"emr_na-hpesbhf03782en_us");
  script_xref(name:"HP", value:"HPESBHF03782");
  script_xref(name:"ZDI", value:"ZDI-17-830");
  script_xref(name:"ZDI", value:"ZDI-17-831");
  script_xref(name:"ZDI", value:"ZDI-17-832");
  script_xref(name:"ZDI", value:"ZDI-17-833");
  script_xref(name:"ZDI", value:"ZDI-17-834");
  script_xref(name:"ZDI", value:"ZDI-17-835");
  script_xref(name:"ZDI", value:"ZDI-17-836");

  script_name(english:"H3C / HPE Intelligent Management Center PLAT < 7.3 E0506P03 Multiple Vulnerabilities");
  script_summary(english:"Checks the version of HPE Intelligent Management Center.");

  script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote Windows host is affected by
multiple vulnerabilities.");
  script_set_attribute(attribute:"description", value:
"The version of HPE Intelligent Management Center (iMC) PLAT installed
on the remote host is prior to 7.3 E0506P03. It is, therefore, affected
by multiple vulnerabilities that can be exploited to execute arbitrary
code.

Note that Intelligent Management Center (iMC) is an HPE product;
however, it is branded as H3C.");
  # https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03782en_us
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?de291610");
  script_set_attribute(attribute:"solution", value:
"Upgrade to H3C / HPE iMC version 7.3 E0506P03 or later.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:F/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:F/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2017-12561");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");
  script_set_attribute(attribute:"exploit_framework_core", value:"true");
  script_set_attribute(attribute:"metasploit_name", value:'HP Intelligent Management Java Deserialization RCE');
  script_set_attribute(attribute:"exploit_framework_metasploit", value:"true");

  script_set_attribute(attribute:"vuln_publication_date", value:"2017/10/03");
  script_set_attribute(attribute:"patch_publication_date", value:"2017/10/03");
  script_set_attribute(attribute:"plugin_publication_date", value:"2017/10/06");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:hp:intelligent_management_center");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Misc.");

  script_copyright(english:"This script is Copyright (C) 2017-2019 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("hp_imc_detect.nbin");
  script_require_ports("Services/activemq", 61616);

  exit(0);
}

include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");

# Figure out which port to use
port = get_service(svc:'activemq', default:61616, exit_on_fail:TRUE);
version = get_kb_item_or_exit('hp/hp_imc/'+port+'/version');

app = 'HP Intelligent Management Center';

fixed_display = '7.3-E0506P03';

fix = "7.3";
patchfix = NULL;

# check patch version if 7.3
if (version =~ "^7.3\-")
{
  # Versions < 7.3 E0506, remove letters and dashes in version
  patch = pregmatch(pattern:"[0-9.]+-E([0-9A-Z]+)", string:version);
  if (!patch) audit(AUDIT_UNKNOWN_APP_VER, app);
  patchver = ereg_replace(string:patch[1], pattern:"[A-Z\-]", replace:".");
  if (!patchver) audit(AUDIT_UNKNOWN_APP_VER, app);

  patchfix = "0506.03";
}

# if pre 7.3 or 7.3 with patchver before 0506
if ((ver_compare(ver:version, fix:fix, strict:FALSE) < 0) ||
    (!isnull(patchfix) && ver_compare(ver:patchver, fix:patchfix, strict:FALSE) < 0))
{
  items = make_array(
    "Installed version", version,
    "Fixed version", fixed_display
  );

  order = make_list("Installed version", "Fixed version");
  report = report_items_str(report_items:items, ordered_fields:order);

  security_report_v4(port:port, extra:report, severity:SECURITY_HOLE);
  exit(0);
}
else
  audit(AUDIT_INST_VER_NOT_VULN, app, version);