Vulnerabilities > Yokogawa > Exaopc
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-04-11 | CVE-2023-26593 | Cleartext Storage of Sensitive Information vulnerability in Yokogawa products CENTUM series provided by Yokogawa Electric Corporation are vulnerable to cleartext storage of sensitive information. | 7.8 |
2022-06-28 | CVE-2022-30707 | Unspecified vulnerability in Yokogawa products Violation of secure design principles exists in the communication of CAMS for HIS. low complexity yokogawa | 8.8 |
2022-03-11 | CVE-2022-21177 | Path Traversal vulnerability in Yokogawa products There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. | 8.1 |
2022-03-11 | CVE-2022-21194 | Use of Hard-coded Credentials vulnerability in Yokogawa products The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00. | 9.8 |
2022-03-11 | CVE-2022-21808 | Path Traversal vulnerability in Yokogawa products Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. | 8.8 |
2022-03-11 | CVE-2022-22141 | Improper Privilege Management vulnerability in Yokogawa products 'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. | 7.8 |
2022-03-11 | CVE-2022-22145 | Resource Exhaustion vulnerability in Yokogawa products CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. | 8.1 |
2022-03-11 | CVE-2022-22148 | Incorrect Permission Assignment for Critical Resource vulnerability in Yokogawa products 'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. | 7.8 |
2022-03-11 | CVE-2022-22151 | Improper Encoding or Escaping of Output vulnerability in Yokogawa products CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00. | 8.1 |
2022-03-11 | CVE-2022-22729 | Improper Authentication vulnerability in Yokogawa products CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. | 8.8 |