Vulnerabilities > Tenda
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-08-07 | CVE-2023-38937 | Out-of-bounds Write vulnerability in Tenda products Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | 9.8 |
2023-08-07 | CVE-2023-38938 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im. | 9.8 |
2023-08-07 | CVE-2023-38939 | Out-of-bounds Write vulnerability in Tenda F1202 Firmware and Fh1202 Firmware Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. | 9.8 |
2023-08-07 | CVE-2023-38940 | Out-of-bounds Write vulnerability in Tenda F1203 Firmware, Fh1203 Firmware and Fh1205 Firmware Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | 9.8 |
2023-07-14 | CVE-2023-37714 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. | 9.8 |
2023-07-14 | CVE-2023-37715 | Out-of-bounds Write vulnerability in Tenda F1202 Firmware and Fh1202 Firmware Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm. | 9.8 |
2023-07-14 | CVE-2023-37716 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | 9.8 |
2023-07-14 | CVE-2023-37717 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | 9.8 |
2023-07-14 | CVE-2023-37718 | Out-of-bounds Write vulnerability in Tenda 4G300 Firmware, F1202 Firmware and Fh1202 Firmware Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter. | 9.8 |
2023-07-14 | CVE-2023-37719 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter. | 9.8 |