Vulnerabilities > Tenda > Fh1202 Firmware
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2024-11-30 | CVE-2024-12002 | NULL Pointer Dereference vulnerability in Tenda products A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. | 6.5 |
2023-08-07 | CVE-2023-38932 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function. | 9.8 |
2023-08-07 | CVE-2023-38938 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im. | 9.8 |
2023-08-07 | CVE-2023-38939 | Out-of-bounds Write vulnerability in Tenda F1202 Firmware and Fh1202 Firmware Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function. | 9.8 |
2023-07-14 | CVE-2023-37714 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. | 9.8 |
2023-07-14 | CVE-2023-37715 | Out-of-bounds Write vulnerability in Tenda F1202 Firmware and Fh1202 Firmware Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm. | 9.8 |
2023-07-14 | CVE-2023-37716 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | 9.8 |
2023-07-14 | CVE-2023-37717 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | 9.8 |
2023-07-14 | CVE-2023-37718 | Out-of-bounds Write vulnerability in Tenda 4G300 Firmware, F1202 Firmware and Fh1202 Firmware Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter. | 9.8 |
2023-07-14 | CVE-2023-37719 | Out-of-bounds Write vulnerability in Tenda products Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter. | 9.8 |