Vulnerabilities > Siemens > Simatic Pcs7 > 7.1
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2017-08-30 | CVE-2017-12069 | XXE vulnerability in multiple products An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. | 6.4 |
2014-11-26 | CVE-2014-8552 | Information Exposure vulnerability in Siemens products The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets. | 5.0 |
2014-11-26 | CVE-2014-8551 | Code Injection vulnerability in Siemens products The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets. | 10.0 |
2014-07-24 | CVE-2014-4686 | Privilege Escalation vulnerability in Siemens Simatic Pcs7 and Wincc The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. network siemens | 6.8 |
2014-07-24 | CVE-2014-4685 | Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic Pcs7 and Wincc Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. | 4.6 |
2014-07-24 | CVE-2014-4684 | Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic Pcs7 and Wincc The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. | 6.0 |
2014-07-24 | CVE-2014-4683 | Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic Pcs7 and Wincc The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. | 4.9 |
2014-07-24 | CVE-2014-4682 | Information Exposure vulnerability in Siemens Simatic Pcs7 and Wincc The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. | 5.0 |
2013-03-21 | CVE-2013-0679 | Path Traversal vulnerability in Siemens Simatic Pcs7 and Wincc Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname. | 4.0 |
2013-03-21 | CVE-2013-0678 | Credentials Management vulnerability in Siemens Simatic Pcs7 and Wincc Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query. | 4.0 |