Vulnerabilities > Siemens > Scalance XC 200 Firmware > 3.0

DATE CVE VULNERABILITY TITLE RISK
2021-07-13 CVE-2020-28400 Allocation of Resources Without Limits or Throttling vulnerability in Siemens products
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition.
network
low complexity
siemens CWE-770
5.0
2021-03-25 CVE-2021-3449 NULL Pointer Dereference vulnerability in multiple products
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client.
5.9
2021-03-15 CVE-2021-25667 Stack-based Buffer Overflow vulnerability in Siemens products
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2).
low complexity
siemens CWE-121
8.8
2020-02-11 CVE-2019-13946 Resource Exhaustion vulnerability in Siemens products
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface.
network
low complexity
siemens CWE-400
7.8
2020-02-11 CVE-2019-13924 Protection Mechanism Failure vulnerability in Siemens products
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl.
network
low complexity
siemens CWE-693
5.4
2019-03-26 CVE-2019-6569 Expected Behavior Violation vulnerability in Siemens products
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network.
network
low complexity
siemens CWE-440
6.4
2017-12-26 CVE-2017-12736 Improper Initialization vulnerability in Siemens products
A vulnerability has been identified in RUGGEDCOM ROS for RSL910 devices (All versions < ROS V5.0.1), RUGGEDCOM ROS for all other devices (All versions < ROS V4.3.4), SCALANCE XB-200/XC-200/XP-200/XR300-WG (All versions between V3.0 (including) and V3.0.2 (excluding)), SCALANCE XR-500/XM-400 (All versions between V6.1 (including) and V6.1.1 (excluding)).
low complexity
siemens CWE-665
5.8