Vulnerabilities > Siemens > Scalance XC 200 Firmware
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2022-08-10 | CVE-2022-36324 | Allocation of Resources Without Limits or Throttling vulnerability in Siemens products Affected devices do not properly handle the renegotiation of SSL/TLS parameters. | 7.5 |
2022-08-10 | CVE-2022-36325 | Unspecified vulnerability in Siemens products Affected devices do not properly sanitize data introduced by an user when rendering the web interface. | 4.8 |
2021-07-13 | CVE-2020-28400 | Allocation of Resources Without Limits or Throttling vulnerability in Siemens products Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. | 7.5 |
2021-03-25 | CVE-2021-3449 | NULL Pointer Dereference vulnerability in multiple products An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. | 5.9 |
2021-03-15 | CVE-2021-25667 | Unspecified vulnerability in Siemens products A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). low complexity siemens | 8.8 |
2020-02-11 | CVE-2019-13924 | Unspecified vulnerability in Siemens products A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. | 5.4 |
2019-08-13 | CVE-2019-10927 | Unspecified vulnerability in Siemens products A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). | 6.5 |
2019-03-26 | CVE-2019-6569 | Unspecified vulnerability in Siemens products The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. | 9.1 |
2017-12-26 | CVE-2017-12736 | Improper Initialization vulnerability in Siemens products A vulnerability has been identified in RUGGEDCOM ROS for RSL910 devices (All versions < ROS V5.0.1), RUGGEDCOM ROS for all other devices (All versions < ROS V4.3.4), SCALANCE XB-200/XC-200/XP-200/XR300-WG (All versions between V3.0 (including) and V3.0.2 (excluding)), SCALANCE XR-500/XM-400 (All versions between V6.1 (including) and V6.1.1 (excluding)). | 8.8 |