Vulnerabilities > Siemens > Medium

DATE CVE VULNERABILITY TITLE RISK
2017-03-29 CVE-2017-2687 Cross-site Scripting vulnerability in Siemens Ruggedcom ROX I 2.9.0
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link.
network
low complexity
siemens CWE-79
6.1
2017-03-29 CVE-2017-2686 Information Exposure vulnerability in Siemens Ruggedcom ROX I 2.9.0
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information.
network
low complexity
siemens CWE-200
6.5
2017-01-30 CVE-2016-2518 Out-of-bounds Read vulnerability in multiple products
The MATCH_ASSOC function in NTP before version 4.2.8p9 and 4.3.x before 4.3.92 allows remote attackers to cause an out-of-bounds reference via an addpeer request with a large hmode value.
network
low complexity
ntp debian netapp oracle redhat freebsd siemens CWE-125
5.3
2017-01-30 CVE-2015-7977 NULL Pointer Dereference vulnerability in multiple products
ntpd in NTP before 4.2.8p6 and 4.3.x before 4.3.90 allows remote attackers to cause a denial of service (NULL pointer dereference) via a ntpdc reslist command.
5.9
2017-01-30 CVE-2015-7973 7PK - Security Features vulnerability in multiple products
NTP before 4.2.8p6 and 4.3.x before 4.3.90, when configured in broadcast mode, allows man-in-the-middle attackers to conduct replay attacks by sniffing the network.
network
high complexity
ntp siemens freebsd netapp canonical CWE-254
6.5
2016-12-17 CVE-2016-9159 Information Exposure vulnerability in Siemens products
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl.
network
high complexity
siemens CWE-200
5.9
2016-11-23 CVE-2016-8672 Information Exposure vulnerability in Siemens products
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl.
network
low complexity
siemens CWE-200
5.3
2016-11-18 CVE-2016-8561 Permissions, Privileges, and Access Controls vulnerability in Siemens Simatic CP 1543-1 Firmware
A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28).
network
high complexity
siemens CWE-264
6.6
2016-11-15 CVE-2016-7165 Improper Access Control vulnerability in Siemens products
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions).
local
high complexity
siemens CWE-284
6.4
2016-10-13 CVE-2016-8564 SQL Injection vulnerability in Siemens Automation License Manager 5.3
SQL injection vulnerability in Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to execute arbitrary SQL commands via crafted traffic to TCP port 4410.
network
low complexity
siemens CWE-89
6.5