2022-01-11 CVE-2021-37196 Path Traversal vulnerability in Siemens Comos
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.3 (All versions >= V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used).
network
siemens CWE-22
3.5
2022-01-11 CVE-2021-37197 SQL Injection vulnerability in Siemens Comos
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used).
network
siemens CWE-89
6.0
2022-01-11 CVE-2021-37198 Cross-Site Request Forgery (CSRF) vulnerability in Siemens Comos
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used).
network
high complexity
siemens CWE-352
5.1
2022-01-11 CVE-2021-41769 Improper Input Validation vulnerability in Siemens products
A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83).
network
low complexity
siemens CWE-20
5.0
2022-01-11 CVE-2021-45033 Use of Hard-coded Credentials vulnerability in Siemens products
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20).
network
siemens CWE-798
8.5
2022-01-11 CVE-2021-45034 Information Exposure Through Log Files vulnerability in Siemens products
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20).
network
siemens CWE-532
4.3
2022-01-11 CVE-2021-45460 Unquoted Search Path or Element vulnerability in Siemens Sicam PQ Analyzer Firmware 3.11
A vulnerability has been identified in SICAM PQ Analyzer (All versions < V3.18).
network
low complexity
siemens CWE-428
5.5
2022-01-10 CVE-2022-0155 Privacy Violation vulnerability in multiple products
follow-redirects is vulnerable to Exposure of Private Personal Information to an Unauthorized Actor
network
low complexity
follow-redirects-project siemens CWE-359
6.5
2022-01-10 CVE-2022-22822 Integer Overflow or Wraparound vulnerability in multiple products
addBinding in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
network
low complexity
libexpat-project tenable siemens debian CWE-190
critical
9.8
2022-01-10 CVE-2022-22823 Integer Overflow or Wraparound vulnerability in multiple products
build_model in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
network
low complexity
libexpat-project tenable debian siemens CWE-190
critical
9.8