Vulnerabilities > Siemens

DATE CVE VULNERABILITY TITLE RISK
2019-01-30 CVE-2018-20749 Out-of-bounds Write vulnerability in multiple products
LibVNC before 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c.
network
low complexity
libvnc-project canonical debian siemens CWE-787
critical
9.8
2019-01-30 CVE-2018-20748 Out-of-bounds Write vulnerability in multiple products
LibVNC before 0.9.12 contains multiple heap out-of-bounds write vulnerabilities in libvncclient/rfbproto.c.
network
low complexity
libvnc-project debian canonical siemens CWE-787
critical
9.8
2019-01-10 CVE-2018-20685 Incorrect Authorization vulnerability in multiple products
In OpenSSH 7.9, scp.c in the scp client allows remote SSH servers to bypass intended access restrictions via the filename of .
5.3
2018-12-19 CVE-2018-20019 Out-of-bounds Write vulnerability in multiple products
LibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code execution
network
low complexity
libvnc-project canonical debian siemens CWE-787
critical
9.8
2018-12-13 CVE-2018-16555 Cross-site Scripting vulnerability in Siemens products
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1).
network
low complexity
siemens CWE-79
5.4
2018-12-13 CVE-2018-13815 Resource Exhaustion vulnerability in Siemens Simatic S7-1200 Firmware and Simatic S7-1500 Firmware
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6).
network
low complexity
siemens CWE-400
7.5
2018-12-13 CVE-2018-13814 Improper Input Validation vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions).
network
low complexity
siemens CWE-20
8.8
2018-12-13 CVE-2018-13813 Open Redirect vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions).
network
low complexity
siemens CWE-601
8.1
2018-12-13 CVE-2018-13812 Path Traversal vulnerability in Siemens products
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions).
network
low complexity
siemens CWE-22
7.5
2018-12-13 CVE-2018-13811 Information Exposure vulnerability in Siemens Simatic Step 7 (Tia Portal)
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1).
local
low complexity
siemens CWE-200
5.5