Vulnerabilities > Selinc > Medium
DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2023-08-31 | CVE-2023-31174 | Cross-Site Request Forgery (CSRF) vulnerability in Selinc Sel-5037 SEL Grid Configurator A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. | 6.5 |
2023-08-31 | CVE-2023-34391 | Incorrect Permission Assignment for Critical Resource vulnerability in Selinc Sel-5033 Acselerator Real-Time Automation Controller Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000. | 5.5 |
2023-05-10 | CVE-2023-2310 | Unspecified vulnerability in Selinc products A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details. | 5.3 |
2023-05-10 | CVE-2023-31150 | Insecure Storage of Sensitive Information vulnerability in Selinc products A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more details. | 6.5 |
2023-05-10 | CVE-2023-31151 | Improper Certificate Validation vulnerability in Selinc products An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated 2022-11-15 for more details. | 4.2 |
2023-05-10 | CVE-2023-31153 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31154 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31155 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31156 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |
2023-05-10 | CVE-2023-31157 | Cross-site Scripting vulnerability in Selinc products An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | 5.4 |