Vulnerabilities > Selinc > Medium

DATE CVE VULNERABILITY TITLE RISK
2023-08-31 CVE-2023-31174 Cross-Site Request Forgery (CSRF) vulnerability in Selinc Sel-5037 SEL Grid Configurator
A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
network
low complexity
selinc CWE-352
6.5
2023-08-31 CVE-2023-34391 Incorrect Permission Assignment for Critical Resource vulnerability in Selinc Sel-5033 Acselerator Real-Time Automation Controller
Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.
local
low complexity
selinc CWE-732
5.5
2023-05-10 CVE-2023-2310 Unspecified vulnerability in Selinc products
A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details.
network
high complexity
selinc
5.3
2023-05-10 CVE-2023-31150 Insecure Storage of Sensitive Information vulnerability in Selinc products
A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more details.
network
low complexity
selinc CWE-922
6.5
2023-05-10 CVE-2023-31151 Improper Certificate Validation vulnerability in Selinc products
An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated 2022-11-15 for more details.
network
high complexity
selinc CWE-295
4.2
2023-05-10 CVE-2023-31153 Cross-site Scripting vulnerability in Selinc products
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.See SEL Service Bulletin dated 2022-11-15 for more details.
network
low complexity
selinc CWE-79
5.4
2023-05-10 CVE-2023-31154 Cross-site Scripting vulnerability in Selinc products
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
network
low complexity
selinc CWE-79
5.4
2023-05-10 CVE-2023-31155 Cross-site Scripting vulnerability in Selinc products
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
network
low complexity
selinc CWE-79
5.4
2023-05-10 CVE-2023-31156 Cross-site Scripting vulnerability in Selinc products
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
network
low complexity
selinc CWE-79
5.4
2023-05-10 CVE-2023-31157 Cross-site Scripting vulnerability in Selinc products
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
network
low complexity
selinc CWE-79
5.4