Vulnerabilities > Schneider Electric > Wiser FOR KNX Firmware

DATE CVE VULNERABILITY TITLE RISK
2022-02-11 CVE-2021-22806 Unspecified vulnerability in Schneider-Electric products
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website.
network
low complexity
schneider-electric
7.5
2022-02-09 CVE-2022-22809 Unspecified vulnerability in Schneider-Electric products
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations.
network
low complexity
schneider-electric
5.3
2022-02-09 CVE-2022-22810 Unspecified vulnerability in Schneider-Electric products
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials.
network
low complexity
schneider-electric
critical
9.8
2022-02-09 CVE-2022-22811 Unspecified vulnerability in Schneider-Electric products
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system?s configurations when an attacker persuades a user to visit a rogue website.
network
low complexity
schneider-electric
8.1
2022-02-09 CVE-2022-22812 Unspecified vulnerability in Schneider-Electric products
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser.
network
low complexity
schneider-electric
6.1
2020-08-31 CVE-2020-7525 Unspecified vulnerability in Schneider-Electric Spacelynk Firmware and Wiser for KNX Firmware
Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used.
network
low complexity
schneider-electric
7.5
2019-09-17 CVE-2019-6832 Improper Authentication vulnerability in Schneider-Electric Spacelynk Firmware and Wiser for KNX Firmware
A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.
network
low complexity
schneider-electric CWE-287
8.3
2018-07-03 CVE-2018-7779 Unspecified vulnerability in Schneider-Electric products
In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access.
network
low complexity
schneider-electric