DATE CVE VULNERABILITY TITLE RISK
2020-12-11 CVE-2020-7560 Write-what-where Condition vulnerability in Schneider-Electric Ecostruxure Control Expert and Unity PRO
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.
6.8
2020-03-23 CVE-2020-7475 Injection vulnerability in Schneider-Electric products
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
network
low complexity
schneider-electric CWE-74
7.5
2020-01-06 CVE-2019-6855 Incorrect Authorization vulnerability in Schneider-Electric products
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
network
low complexity
schneider-electric CWE-863
7.5
2017-02-13 CVE-2016-8354 Code Injection vulnerability in Schneider-Electric Unity PRO 11.0/6.0/7.0
An issue was discovered in Schneider Electric Unity PRO prior to V11.1.
network
high complexity
schneider-electric CWE-94
5.1
2015-02-01 CVE-2014-9200 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Schneider-Electric products
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
network
low complexity
schneider-electric CWE-119
7.5
2014-04-01 CVE-2013-0662 Out-of-bounds Write vulnerability in Schneider-Electric products
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
network
schneider-electric CWE-787
critical
9.3
2011-11-04 CVE-2011-3330 Improper Restriction of Operations Within the Bounds of A Memory Buffer vulnerability in Schneider-Electric products
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.
local
low complexity
schneider-electric CWE-119
7.2