Vulnerabilities > Schneider Electric > Medium

DATE CVE VULNERABILITY TITLE RISK
2020-12-11 CVE-2020-7541 Unspecified vulnerability in Schneider-Electric products
A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.
network
low complexity
schneider-electric
5.3
2020-12-11 CVE-2020-28220 Unspecified vulnerability in Schneider-Electric Modicon M258 Firmware, Somachine and Somachine Motion
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.
low complexity
schneider-electric
6.8
2020-12-11 CVE-2020-28218 Unspecified vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2/2.7
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action.
network
low complexity
schneider-electric
6.5
2020-12-11 CVE-2020-28214 Unspecified vulnerability in Schneider-Electric Modicon M221 Firmware
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide.
local
low complexity
schneider-electric
5.5
2020-12-01 CVE-2020-7546 Unspecified vulnerability in Schneider-Electric products
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
network
low complexity
schneider-electric
5.4
2020-11-19 CVE-2020-7573 Unspecified vulnerability in Schneider-Electric Webreports 1.9/3.1
A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.
network
low complexity
schneider-electric
6.5
2020-11-19 CVE-2020-7571 Unspecified vulnerability in Schneider-Electric Webreports 1.9/3.1
A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.
network
low complexity
schneider-electric
5.4
2020-11-19 CVE-2020-7570 Unspecified vulnerability in Schneider-Electric Webreports 1.9/3.1
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Stored) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and achieve a Cross-Site Scripting stored attack against other WebReport users.
network
low complexity
schneider-electric
5.4
2020-11-19 CVE-2020-7568 Unspecified vulnerability in Schneider-Electric Modicon M221 Firmware
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
low complexity
schneider-electric
4.3
2020-11-19 CVE-2020-7567 Unspecified vulnerability in Schneider-Electric Modicon M221 Firmware
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys.
low complexity
schneider-electric
5.7