Vulnerabilities > Schneider Electric > Medium

DATE CVE VULNERABILITY TITLE RISK
2019-11-20 CVE-2019-6853 Cross-site Scripting vulnerability in Schneider-Electric products
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
network
low complexity
schneider-electric CWE-79
6.1
2019-10-29 CVE-2019-6847 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6846 Cleartext Transmission of Sensitive Information vulnerability in Schneider-Electric products
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
network
low complexity
schneider-electric CWE-319
6.5
2019-10-29 CVE-2019-6844 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6843 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6842 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6841 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-09-17 CVE-2019-6838 Unspecified vulnerability in Schneider-Electric products
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file.
network
low complexity
schneider-electric
6.5
2019-09-17 CVE-2019-6835 Cross-site Scripting vulnerability in Schneider-Electric products
A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.
network
low complexity
schneider-electric CWE-79
5.4
2019-09-17 CVE-2019-6833 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received.
network
low complexity
schneider-electric CWE-754
6.5