DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-07-23 | CVE-2020-7514 | Use of a Broken or Risky Cryptographic Algorithm vulnerability in Schneider-Electric Easergy Builder 1.4.7.2 A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker access to the authorization credentials for a device and gain full access. | 7.8 |
2020-07-23 | CVE-2020-7491 | Unspecified vulnerability in Schneider-Electric products **VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. | 7.5 |
2020-06-16 | CVE-2020-7513 | Cleartext Storage of Sensitive Information vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to intercept traffic and read configuration data. | 7.5 |
2020-06-16 | CVE-2020-7511 | Use of a Broken or Risky Cryptographic Algorithm vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to acquire a password by brute force. | 7.5 |
2020-06-16 | CVE-2020-7510 | Information Exposure vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-200: Information Exposure vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow attacker to obtain private keys. | 7.5 |
2020-06-16 | CVE-2020-7509 | Improper Privilege Management vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-269: Improper privilege management (write) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to elevate their privileges and delete files. | 7.2 |
2020-06-16 | CVE-2020-7507 | Resource Exhaustion vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-400: Uncontrolled Resource Consumption vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to login multiple times resulting in a denial of service. | 7.5 |
2020-06-16 | CVE-2020-7506 | Unspecified vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-200: Information Exposure vulnerability exists in Easergy T300, Firmware V1.5.2 and prior, which could allow an attacker to pack or unpack the archive with the firmware for the controller and modules using the usual tar archiver resulting in an information exposure. | 7.5 |
2020-06-16 | CVE-2020-7505 | Download of Code Without Integrity Check vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-494 Download of Code Without Integrity Check vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to inject data with dangerous content into the firmware and execute arbitrary code on the system. | 7.2 |
2020-06-16 | CVE-2020-7503 | Cross-Site Request Forgery (CSRF) vulnerability in Schneider-Electric Easergy T300 Firmware 1.5.2 A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to execute malicious commands on behalf of a legitimate user when xsrf-token data is intercepted. | 8.8 |