DATE | CVE | VULNERABILITY TITLE | RISK |
---|---|---|---|
2020-11-19 | CVE-2020-7559 | Unspecified vulnerability in Schneider-Electric Ecostruxure Control Expert A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | 7.5 |
2020-11-19 | CVE-2020-7558 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7557 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7556 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7555 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7554 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7553 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7552 | Out-of-bounds Write vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7551 | Out-of-bounds Write vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |
2020-11-19 | CVE-2020-7550 | Unspecified vulnerability in Schneider-Electric Interactive Graphical Scada System A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | 7.8 |