Vulnerabilities > Schneider Electric

DATE CVE VULNERABILITY TITLE RISK
2019-10-29 CVE-2019-6844 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6843 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6842 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-10-29 CVE-2019-6841 Improper Handling of Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol.
network
low complexity
schneider-electric CWE-755
4.9
2019-09-17 CVE-2019-6840 Use of Externally-Controlled Format String vulnerability in Schneider-Electric products
A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.
network
low complexity
schneider-electric CWE-134
critical
9.8
2019-09-17 CVE-2019-6839 Unrestricted Upload of File with Dangerous Type vulnerability in Schneider-Electric products
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file.
network
low complexity
schneider-electric CWE-434
8.8
2019-09-17 CVE-2019-6838 Unspecified vulnerability in Schneider-Electric products
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file.
network
low complexity
schneider-electric
6.5
2019-09-17 CVE-2019-6837 Server-Side Request Forgery (SSRF) vulnerability in Schneider-Electric products
A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could cause server configuration data to be exposed when an attacker modifies a URL.
network
low complexity
schneider-electric CWE-918
critical
9.1
2019-09-17 CVE-2019-6836 Unspecified vulnerability in Schneider-Electric products
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.
network
low complexity
schneider-electric
7.5
2019-09-17 CVE-2019-6835 Cross-site Scripting vulnerability in Schneider-Electric products
A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.
network
low complexity
schneider-electric CWE-79
5.4