Vulnerabilities > Schneider Electric

DATE CVE VULNERABILITY TITLE RISK
2020-03-23 CVE-2020-7475 Injection vulnerability in Schneider-Electric products
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
network
low complexity
schneider-electric CWE-74
critical
9.8
2020-03-23 CVE-2020-7474 Uncontrolled Search Path Element vulnerability in Schneider-Electric Pmepxm0100 Prosoft Configurator 1.002
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProSoft Configurator (v1.002 and prior), for the PMEPXM0100 (H) module, which could cause the execution of untrusted code when using double click to open a project file which may trigger execution of a malicious DLL.
local
low complexity
schneider-electric CWE-427
7.8
2020-01-22 CVE-2019-6858 Uncontrolled Search Path Element vulnerability in Schneider-Electric MSX Configurator
A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL.
local
low complexity
schneider-electric CWE-427
7.8
2020-01-06 CVE-2019-6857 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
network
low complexity
schneider-electric CWE-754
7.5
2020-01-06 CVE-2019-6856 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
network
low complexity
schneider-electric CWE-754
7.5
2020-01-06 CVE-2019-6855 Incorrect Authorization vulnerability in Schneider-Electric products
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
network
low complexity
schneider-electric CWE-863
7.3
2020-01-06 CVE-2019-6854 Unspecified vulnerability in Schneider-Electric Clearscada 2017
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files.
local
low complexity
schneider-electric
7.8
2020-01-06 CVE-2018-7794 Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider-Electric products
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
network
low complexity
schneider-electric CWE-754
7.5
2019-11-20 CVE-2019-6853 Cross-site Scripting vulnerability in Schneider-Electric products
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
network
low complexity
schneider-electric CWE-79
6.1
2019-11-20 CVE-2019-6852 Information Exposure vulnerability in Schneider-Electric products
A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.
network
low complexity
schneider-electric CWE-200
7.5